The 6,500-H Life Test Results of 30 cm Diameter Ion Thruster
Keywords:
Thruster, Life test, Performance, Erision, Grid gapAbstract
The life test of the 30 cm diameter ion thruster developed by the Lanzhou institute of physics began in Apr. 2018 and ended in Jan. 2020, lasting 6,500 h. This paper introduces the results of the 6,500-h life test of the 30 cm diameter ion thruster completed on the ground, including the ground facility for life test, the variations of the thrusters working performance, the times of the breakdown and power restart, and the erosion of the key components. The results show that the performance parameters, such as thrust, specific impulse and efficiency, do not change obviously during the test and magnetic field of the discharge chamber has no change. With the increase of test time, breakdown times increased significantly, whereas the power restart time decreased correspondingly. The diameter of the cathode orifice decreases gradually and there is a blockage risk of orifice. However, the diameter of the keeper orifice increases and presents an inverted cone erosion pattern. The diameter of the decelerator grid aperture expanded from 1.6 to 1.8 mm from 0 to 1,000 h and slightly enlarged after that. The aperture diameter of the accelerator grid presented linear enlargement but the pits-and-grooves erosion is obvious.Downloads
Published
2021-02-10
Issue
Section
Original Papers
License
This work is licensed under a Creative Commons — Attribution 4.0 International — CC BY 4.0. Authors are free to Share (copy and redistribute the material in any medium or format) and Adapt (remix, transform, and build upon the material for any purpose, even commercially). JATM allow the authors to retain publishing rights without restrictions.