Effects of Magnetic Shielding Configuration on Discharge Characteristics and Performance of a 60 mm-Diameter Low-Power Hall Thruster
Keywords:
Hall thruster, Magnetic shielding, Performance, Lifetime TestAbstract
Lifetime is a main factor restraining the application of low-power Hall thruster. Magnetic shielding configuration is regarded as a promising method to prolong the lifespan of Hall thruster. Aiming to demonstrate the feasibility and effectiveness of magnetic shielding configuration applying on low-power Hall thruster, a 60-mm diameter Hall thruster in partial magnetic shielding configuration was designated. Both the numerical and experimental methods were used to investigate the discharge characteristics of the Hall thruster and help understand the mechanism behind. The maximum anode efficiency was achieved as high as 29.7% with 1.7 mg·s–1 anode mass flow and 320 V discharge voltage. To evaluate the effectiveness of the magnetic shielding used for low-power Hall thruster, a 2000 h lifetime test has been carried out and the results indicate that the erosion rate has been decreased below 0.2 μm·h–1.Downloads
Published
2021-05-21
Issue
Section
Original Papers
License
This work is licensed under a Creative Commons — Attribution 4.0 International — CC BY 4.0. Authors are free to Share (copy and redistribute the material in any medium or format) and Adapt (remix, transform, and build upon the material for any purpose, even commercially). JATM allow the authors to retain publishing rights without restrictions.